Axial Blower – WFSL
AXIAL BLOWER with WBI/WBD Thrust Restraints mounted on WFSL Base with height saving brackets, high deflection SLF Mounts and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors.
AXIAL BLOWER with WBI/WBD Thrust Restraints mounted on WFSL Base with height saving brackets, high deflection SLF Mounts and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors.
HVAC UNIT directly mounted on 1″ deflection SSLFH Spring Mounts. Reinforced housekeeping pad secured by HPA Anchors. SAFEFLEX Expansion Joints are installed in pipelines to reduce blade frequency vibration and noise and to allow for seismic displacement.
HVAC UNIT on steel base with height saving brackets, high deflection SLF Spring Mounts and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors. SAFEFLEX Expansion Joints are installed in pipelines to reduce blade frequency vibration and noise and to allow for seismic displacement.
HVAC UNIT suspended from RW30N Hangers and restrained by SCB Cable Assemblies in four corners. SAFEFLEX Expansion Joints are installed in pipelines to reduce blade frequency vibration and noise and to allow for seismic displacement.
END SUCTION PUMP on WFSL Base with height saving brackets, MT Air Springs and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors. SAFEFLEX Expansion Joints are installed in pipelines to reduce blade frequency vibration and noise and to allow for seismic displacement.
DOUBLE SUCTION PUMP on concrete filled BMK Base with height saving brackets, high deflection SLF Spring Mounts and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors. SAFEFLEX Expansion Joints are installed in pipelines to reduce blade frequency vibration and noise and to allow for seismic displacement.
END SUCTION PUMP on WFSL Base with height saving brackets, high deflection SLF Mounts and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors. SAFEFLEX Expansion Joints are installed in pipelines to reduce blade frequency vibration and noise and to allow for seismic displacement.
STEAM GENERATOR directly mounted on SLR Restrained Spring Mounts. Reinforced housekeeping pad secured by HPA Anchors.
HORIZONTAL TANK TYPE COMPRESSOR directly mounted on SLR Restrained Spring Mounts. Reinforced housekeeping pad secured by HPA Anchors.
VERTICAL TANK TYPE COMPRESSOR directly mounted on BMK Concrete Filled Base, 1″ deflection SLF Mounts and Z-1011 Seismic Restraints. Reinforced housekeeping pad secured by HPA Anchors.